Overall Experience
Quality
Price
Convenience
I asked for my French drain to be jetted of roots to help clear out the clog they are causing. The technician didn’t do it and not helped clear some water backed up. This is now the 4th service in a row LBA has done for me where the team did a poor job.
Overall Experience
Quality
Price
Convenience
I’m surprised he didn’t do anything to see why the sump pump isn’t working. But he was friendly and professional
Overall Experience
Quality
Price
Convenience
Johann and team were respectful, quiet, and efficient. Showed up on time and got the work done.
Overall Experience
Quality
Price
Convenience
Airflow specialist Jared help me make an informed decision about my 25 year old unit.
Overall Experience
Quality
Price
Convenience
JJ is an HVAC phenom. He’s been repairing units since before he could drive. Informed and experienced bright young man.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Extremely knowledgeable and helpful
Response from LBA Air Conditioning, Heating & Plumbing:
We thank you for sharing your positive experience. It made our day.
Overall Experience
Quality
Price
Convenience
Cornelius is very professional, personable & provides great service
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Went for a maintenance call today for heat. Tested for static pressure system is passing when in heat. All electrical components are passing for manufacture specifications. Did a combustion test is within range. Inspected heat exchanger no cracks/leaks were detected. Did notice some rust in the eye lids of heat exchanger and showed customer.Checked temp split and is passing. Cleaned flame sensor and pressure switch hose. Did replace water panel for customer and humidifier is running.System is up and running before departure. Thank you for choosing LBA services-Johann
Completed furnace, maintenance and inspection. I cleaned flame sensor and wiped down furnace. I checked amp draws and components. I tested airflow, pressure and temp splits. I tested humidifier operations and found that the humidifier did not have any water running to it. The quarter turn valve was clogged up with hard water deposit. The water resistor in the water tube, most likely cause this. I took out the water resistor and was able to clear out the quarter turn valve so the humidifier is working properly. Furnace is operating within manufacture specifications at departure.
Customer called in about gas leak coming from supply line to the stove. Verified gas leak coming from reducer fitting on supply line. Noticed gasline goes from 3/4” to 1/2” back to 3/4”. Gas line threads has plumbers Teflon tape instead of pipe dope. Also where gas leak was detected, the gas appliance line was not properly installed to gas shut off valve. It was missing sealant causing gas leak. Gave options to customer and customer chose to just have the supply line replaced. Went ahead and installed new gas appliance connector to stove. Checked for gas leaks and no leaks detected.
Arrived for no heat call. I found the thermostat wiring was wrong. Fixed that and got the call for heat and ac. I had to give the inducer a little boost to start it, and I cleaned the flame sensor. Cycled heat a few times and stated up. Cycled to ac and it started. System is running upon departure.
Went for a maintenance call for heat. Tested for static pressure, system is passing for static in heat. All electrical components are passing for system. Did a combustion test is within range passing. Inspected heat exchanger no wear and tear. Did clean flame sensor, and pressure switch hose. As well replaced filter for customer. System is up and running before leaving. Thank you for choosing LBA services-Johann
Arrived to do a performance maintenance. Set up for combustion analysis temperature split and static pressure tests. Verified operation of all mechanical and electronic components of the furnace. Checked blower for cleanliness and to see if there is any play in the bearings. Checked systems heat exchanger to ensure proper venting of flue gas. Performed an electronic gas leak search. Furnace and humidifier are operational at this time.
Unit is operating properly. Amperage for compressor and fan are passing. No sound was coming from system as of today visit. System is up and running before leaving. Thank you for choosing LBA services- Johann
Went for a service call today. Good airflow and clean filter inside. Outside compressor was running weak. Checked the capacitor it had failed on the compressor side. Replaced the capacitor and the system is up and cooling. Thank you for choosing LBA services!
Arrived to remedy an inoperable system. Upon arrival homeowner walked me around to the outside unit. Started testing components of the system. Found that the capacitor is failing. This would cause the compressor to not operate. Without refrigerant flow the system can’t cool. Replaced the capacitor to test system operation. System is operating with a new capacitor installed. Spoke with homeowner about repair solutions. Sold the already done capacitor replacement and signed the homeowner up for the maintenance membership. This way we can come out and perform maintenances and make sure there are not any uncomfortable days in the home. System is operational upon departure.
Installed 80% full system and charged to 10° subcool
Sold 3 ton 14 seer AC/Coil & 80% 100k btu furnace $11,110.70
Arrived for ac check. Upon arrival the main system was not working and one of the mini spots was froze up. My supervisor came out to help start diagnosis on systems. He discussed best solutions.
Arrived to remedy a leaking minisplit system. Upon inspection of the system found water dripping from all points of the frame of the unit, despite it having a condensate pump. Inspected the condensate pump and verified it is working and draining water properly. Determined there is a restriction or blockage in the drain to the condensate pump. Spoke with homeowner about what the minisplit is doing and how the other 3 units are likely not far behind this one. With homeowners approval cleared the blockage and flushed the condensate pan. Installed a gel tab in the condensate pan. Reassembled the minisplit and verified operation. Disassembled the other 3 heads no installed gel tabs to help ensure they will continue to operate without issue. All systems are operational upon departure.